Oscilloscopes
Since the oscilloscope and probe become part of the circuit being tested, it is also necessary to understand and apply the information on the oscilloscope probes page. If in doubt (especially about safety), please ask before damaging scopes or people.
Safety
Oscilloscopes can be used dangerously, especially when connecting to anything connected to the mains voltages, and it is easy for a beginner to make a subtle mistake. Getting it wrong can result in loud noises followed by deathly slience.
- obviously electrocution is a potential danger, but incorrect connections can also melt scope probes, cause fires, as well as destroying the scope or unit being tested.
- you may be surprised how mains earths can and do cause those problems.
- internally scopes contain >8kV, and they can retain the charge long after the scope is switched off.
Read and understand the references in the 'Formal' and 'Praxis' sections of this page, and Tektronix' ABCs of Probes Primer pp55-56 - and apply the knowledge before you make a connection.
Summary:
- probe class: choose a suitable class (EHT, HV differential, etc) probe for your measurement
- voltage limits, don't forget:
- oscilloscope (including input coupling)
- probe (including derating at high frequencies)
- high voltages: don't probe anything >50V without an EHT probe or an HV differential probe
- earthed shields: if you connect a probe shield to anything other than earth, high currents will flow since the case is earthed. If you forget that, then see EEVblog #279 How NOT To Blow Up Your Oscilloscope!
- floating measurements: to measure voltages not earth referenced, use an HV differential probe. See Fundamentals of Floating Measurements and Isolated Input Oscilloscopes
- never ever ever “float a scope” by disconnecting its ground lead, unless you also fully implement the mods shown in this page's footnote. Then don't do it; use the right probe
- accidental shorts: due to slipped ground leads and exposed probe tip ground, or the tip shorting adjacent tracks/pins
- overvoltage: a *1/*10 probe switched to *1
- voltage not divided: a cheap *100/*1000 probe plus scope AC coupled puts the whole mean input voltage across the scope's input capacitor, not 1/100 or 1/1000
- 50ohm resistor melting: a scope with a 50ohm input impedance has a very limited input voltage spec
- CRT brightness: don't have it too bright or too dim:
- a bright unchanging display can cause irreversible phosphor burn
- leaving the spot in a single place (XY mode) can irreversibly warp an expansion mesh (and therefore warp the display) or overheat and crack the CRT
- conversely, if the brightness is left turned right down, then the tube can be destroyed by cathode poisioning
Do not, under any circumstances whatsoever, disconnect an earth; the results can kill you or - worse - can kill someone else. Use the proper type of probe! (If you really think you need to “float a scope” see the picture in the footnote to understand the necessary minimum. Then don't do it :) )
Do not use any of HackSpace's scope probes for measuring mains equipment and voltages, and that includes inside SMPSs.
General
Understand how to use them safely before using them.
This page summarises our scopes in terms of their target application domains, who might use them, and where they can be stored. The “Specific Features” section lists unique benefits. From this we can choose which scopes to cull, and to see what would be interesting in the future.
One way of categorising scopes is by how often we expect to use them, which translates into where they should be stored (this will be updated after the move):
- electronics test bench: small, robust, easy-to-use scopes for casual use and everyday tasks
- accessible shelf over the electronics test bench: unique features necessary for specific tasks, but may be large or awkward
- high shelf elsewhere in G11: unique but flawed, or duplicated capabilities, or used if several scopes are required simultaneously for workshops
- we have disposed of some scopes, because they were poor quality or we had too many duplicates or they were slightly faulty. Details have been removed from this page, but can be found via the “Old revisions” link at the top of the page
Another is by target application domain likely to be found in typical HackSpace projects. There is significant overlap between categories, and there are many other application domains.
Oscilloscopes are useless on their own - they also need probes to connect to the circuit. Probes are surprisingly fragile and significantly affect your measurements - see the Oscilloscope Probe page for more information. Note than none of the HackSpace probes are suitable for measuring mains voltages directly.
Using Our Oscilloscopes
Test Bench | Accessible Shelf | High Shelf | Dispose | Typical spec and examples | |
---|---|---|---|---|---|
Audio | Kenwood CS4125 | Metrotest OX8020 | <100kHz, mV - audio signals, sensors | ||
Mechatronics | Kenwood CS4125 | Metrotest OX8020 | <10MHz, 50mV-50V, - motors, actuators, machines | ||
Agilent 54621 | |||||
Digital | Agilent 54621 | IsoTech ISR-1014 | <=60MHz, 500mV-5V, - well-behaved logic e.g. Arduino | ||
Tektronix 2245 | |||||
Signal Integrity | Tektronix 2245 | >=100MHz, 500mV-5V, medium-speed logic and checking valid logic levels, e.g. generic TTL, CMOS | |||
IsoTech ISR-1014 | |||||
High-speed | - | - | - | - | >=250MHz, note not MS/s! |
Specific Features
Important features indicated by emphasis.
Location: Electronics Test Bench
Location: Accessible Shelf Above Test Bench
IsoTech ISR-1014 | Tektronix 2245 | |
---|---|---|
Location | Test bench shelf | Test bench shelf, to reduce chance of accidental damage |
Domain | Medium speed digital, signal integrity | Medium speed digital, signal integrity |
Specification | 100MHz, analogue, 4 channel, OSD | 100MHz, analogue, 4 channel, OSD |
Autosetup | Autosetup | |
Manual time/freq/voltage measurements | Manual time/freq/voltage measurements | |
Condition | Fully functional | Fully functional |
Plan on replacing X/Y mains capacitors plus electrolytics | ||
May need to replace calibration battery | ||
Comments | First choice fast scope | First choice fast scope |
Equivalent to the Tek 2245, but softbutton menus slightly less suitable for casual use | Move “soft knobs” in both directions, including after autosetup | |
Small size/weight | Medium size/weight | |
OUT OF ACTION. Do NOT use. An unknown person “floated” this scope by disconnecting the protective mains earth. Apart from being lethally dangerous as noted above, it may have been damaged internally. It has been PAT tested, but must be disassembled and the PSU capacitors checked and/or replaced by a person skilled in that task. | ||
USP | Fast, 4 channels | Fast, 4 channels, excellent triggering, standard controls |
![]() | ![]() |
Location: High Shelf
For Disposal
Since they were either faulty or a pain to use, and we had better scopes with these features, in February 2019 we disposed of these scopes: Wavetek 9020, Gould OS300, Tek TDS340, Schlumberger 5602.C, Hameg HM203.
To make more room and to reduce the equipment that needed to be moved to the new premises, in October 2020 we disposed of the Tektronix DM63 and the Topward 7042.
If you want to see their features, look at an earlier revision of this page.